  CERTIFIED Independent Laboratory Test

Performed by an independent third party lab
08 March 91 Analysis No. 15836
Again on 28 August 1992
Analysis No. 15836-A NSF 53-88
Douglas MacGregor

  Analysis
Test Results Summary of Wholly Water ®

Under NSF-53 Protocol Chemical Challenge Tests

Drinking and cooking water consumption for a typical family of four averages less than 2,000 gallons per year. The results summarized in the table below are the readings taken at roughly 50 percent of the manufacturer’s rated capacity of 38,987 gallons from a listed capacity of 77,974 gallons.

Gallons Serviced: 19,952 @ 1 Gallon Per Minute Flow Rate

MCL Chemical Concentration
ppm (mg/L)

NSF Protocol Maximum Allowed Input
Water
Unit
Output
% MCL
Reduced
         
Trihalomethane (TTHM)
(as CHC13)
< 0.1 0.49 0.01

98%

Lead (as PbC12) < 0.02 0.15 0.001

99%

Fluoride < 2.0 8.17 0.027 99%
Nitrate (as N) < 10.0 30.0 1.02 97%
Barium < 1.0 10.0 0.020 99%
Arsenic < 0.05 0.31 0.000 100%
Cadmium < 0.005 0.030 0.000 100%
Chromium +3 < 0.05 0.15 0.004 97%
Chromium +6 < 0.05 0.153 0.004 97%
Selenium < 0.01 0.100 0.000 100%
Mercury < 0.002 0.006 0.000 100%
Lindane < 0.0002 0.0006 0.0000 100%
Methoxychlor < 0.1 0.32 0.003 99%
Toxaphene < 0.005 0.016 0.000 100%
2, 4-D < 0.07 0.31 0.003 99%
Silvex (2,4, 5-TP) < 0.01 0.033 0.002 94%
Trichloroethylene < 0.005 0.300 0.001 99%

NSF-42 protocol tests for taste, odor & chlorine removal 99.99%
NSF bacteriological protocol test

      Bacteria Plate Count % Bacteria
Time %Life Condition Influent Effluent Reduced
Pretest   Source Water 510    
    60 Hr Stagnation 650    
Startup 0% Challenge Start 500 80 84%
Day 2   Low TDS Water Test 80 Vol
+ 8 hr. Shutdown, Run to 100 Vols
520 65 88%
  50% 8 Hour Shutdown 500 50 90%
  75% 8 Hour Shutdown 510 60 89%
  90% Start 60 Hour Shutdown 500 60 88%
    Restart Test 510 7 99%
  100% 8 Hour Shutdown 520 65 88%
  120% Starts High TDS Test 80 Vol.
+ 8 Hr. Shutdown
500 55 89%
    Resume High TDS to 100 Vols.
Start Low TDS Water Test
At 80 Vols + 8 Hour Shutdown
520 60 89%

Other chemical toxins removed or significantly reduced when NSF challenge water is passed through the Wholly Water ® Appliance:

Organic Volatiles
Benzene 2, 2-Dichloropropene Dieldrin
Vinyl chloride Ethylenedibromide (EDB) Heptachlor
Carbon tetrachloride Ethylbenzene Heptachlor Epoxide
1, 2-Dichloroethane 1, 1, 2-Trichloroethane Hexachlorobenzene
1, 4-Dichlorobenzene 1, 1, 1, 2-Tetrachloroethane Hexachloropentadine
1, 1-Dichloroethylene 1, 1, 2, 2-Tetrachloroethane PCBs
1, 1, 1-Trichloroethane Tetrachloroethylene (PCE) Pentachloronitrobenzene
Bromobenzene 1, 2, 3-Trichloropropane Simazine
Bromoethane Toluene Trifluralin
Chlorobenzene Xylene
Chloroethane Chloroethylvinylether Inorganic Metals
Chloromethane Dichlorodifluoromethane Iron
2-Chlorotoluene 1, 3-Dichloropropane Nickel
4-Chlorotoluene Trichlorofluoromethane Silver
Dibromochloropropane (DBCP) Trichlorobenzene(s)
Dibromomethane Endrin Organic
1, 2-Dichlorobenzene Trihalomethanes
1, 3-Dichlorobenzene Organic Herbicides Bromoform
Trans-1, 2-Dichloroethylene Pesticides, PCBs Bromodichloromethane
Cis-1, 3-Dichloroethylene Alachlor Chloroform
Dichloromethane Aldrin Dibromochloromethane
1, 1-Dichloroethane Atrazine
1, 1-Dichloropropene Chlordane Other Inorganics
1, 2-Dichloropropane Dichloran Foaming Agents
Cis-1, 3-Dichloropropene   Odor Threshold

Independent Third Party General Performance Test
Independent Third Party Lab Cycle Tests
NSF 53 @ 100% 77,974 Gallons Listed Capacity.
NSF 53 Chemical Challange Test for Health Effects Page 1
NSF 53 Chemical Challange Test for Health Effects Page 2
NSF 53 Chemical Challange Test for Health Effects Page 3
NSF 42 Taste & Odor Perforamance: Class 1 Compliance 220,490 Gallons.
NSF 53 Volatile Organic Carbon Test 2 @ 5,000 Gallons.
NSF 53 Volatile Organic Carbon Test 3 @ 10,000 Gallons.
NSF 53 Volatile Organic Carbon Test 4 @ 15,000 Gallons.
NSF 53 Volatile Organic Carbon Test 5 @ 18,000 Gallons.
NSF 53 Volatile Organic Carbon Test 6 @ 20,000 Gallons.
NSF 53 Volatile Organic Carbon Test 7 @ 40,000 Gallons.

  More Wholly Water ® Tests including Arsenic

Government of the People’s Republic of Bangladesh Department of Environment letter of Certification

Bangladesh Council of Scientific and Industrial Research (BCSIR)

Bangladesh University of Engineering & Technology (BUET)

International Center for Diarrhoeal Disease Research, Bangladesh (ICDDRB)

Note: BSTI ( Bangladesh Standards & Testing Institution) has accepted Wholly Water ® for commercial bottling water plants.

ETV-AM Certificate from BCSIR ( Under Ministry of Science and Technology) ETV-AM ( Environmental technology Verification - Arsenic Mitigation ) is a very rare & authentic certification, not only in Bangladesh, but in countries all over the world.
WHOLLY WATER ® is one of only 4 technologies that has passed the first phase of this testing
and will soon hold this valuable certification.